Wooden sliding panels solve a problem that hinged doors and fixed joinery cannot: they close off a closet, divide a suite or hide a media wall without swinging into the room. They also fail in a very specific way. When the opening, the track and the panel sizes are not agreed between the drawing set and the completed shell, the panels bind, overlap badly or leave gaps that no amount of site adjustment can fix. The coordination work happens before production, and it is where project owners, designers and contractors should spend their attention.

This guide sets out what to put on the drawings, what to confirm on site, and how a made-to-measure supplier turns both into a panel system that fits the opening it was designed for.

Where wooden sliding panels are used in villa and hospitality projects

Across the villa and hospitality work this range covers, wooden sliding panels appear in four recurring situations, and each one puts different pressure on the drawings:

  • Closet and wardrobe fronts. Panels close a recessed dressing area where a hinged door would clash with beds, vanities or circulation. See closet sliding panels.
  • Room dividers. A panel system separates a bedroom from a study, or a suite from a lounge, and has to work both as an acoustically useful divider and as a visible finish surface. See partition sliding systems.
  • Media and display walls. Panels slide across to reveal or conceal a screen, shelving or artwork. See sliding panel TV systems.
  • Acoustic and textured screens. Where speech privacy matters, panel build-up and sealing matter just as much as the finish. See acoustic sliding panels.

The same coordination logic applies whether the panel is part of a villa in Sydney or Melbourne, a hotel guest room, or an office fit-out. What changes is who signs off the drawing and how many trades share the wall.

What the design drawings must state

A panel schedule that only shows an elevation and a finish code is not enough to manufacture or install. Before a sliding panel system can be quoted, the following needs to be fixed on paper. If any of it is missing, the drawing is still conceptual rather than production-ready.

Drawing itemWhy it matters
Clear opening width and height, at head, middle and sillPanels are cut to the opening. Three height readings on one opening show whether the floor or lintel is out of level, which decides how much adjustment the track can absorb.
Finished floor and finished wall levelsPanels are dimensioned to finishes. If screed, tiling or cladding thickness is not shown, the panel either drags on the floor or leaves a visible gap.
Track position: ceiling-mounted, wall-hung or floor-guidedEach option needs different structure above or beside the opening, and each behaves differently over tiled and timber floors.
Structure behind the fixing lineTimber or steel blocking, a backing batten or a structural lintel must be shown on the drawing so the builder installs it before the wall is closed.
Panel count, stack direction and overlapWhere the panels park when open determines usable wall length, handle positions and whether the opening is fully or partly clear.
Finish schedule: substrate, veneer or lacquer, grain directionWood-grain finishes read differently at scale. Grain direction and panel joints should be drawn, not left to the factory.
Adjacent services and ironmongerySockets, switches, curtain boxes, door frames and skirting returns all sit on the same wall and must be dimensioned against the panel travel.

Where the panel system is designed alongside other joinery, interior design services cover layout planning, furniture layouts and 3D renderings, plus drawing and production coordination. That step is where the panel schedule gets reconciled with cabinetry, wall panelling and door schedules in one set instead of three.

What to verify on site before ordering

Drawings describe intent; the completed shell decides fit. A short site check, ideally by the same person who took the drawing dimensions, prevents most call-backs:

  • Re-measure the finished opening. Take the measurement after screed, plasterboard, tiling and floor finishes are in place. Record width at three points and height at three points, and note the largest deviation.
  • Check level and plumb across the whole run. A single track spanning several bays amplifies small deviations. Note whether the deviation can be taken up by the track or needs packing at the structure.
  • Confirm floor type along the travel path. Tile, stone, engineered timber and carpet thresholds behave differently under a bottom guide. Threshold details should be agreed with the flooring supplier, not assumed.
  • Confirm the structure can carry the hardware. Sliding hardware loads the head structure point by point. Where the ceiling is a suspended or lightweight system, blocking must be designed and installed.
  • Check clearances for door and panel travel. Skirting, architraves, radiator positions and wall lights all reduce the space a panel can slide into.
  • Agree who supplies what. Track and hardware, glass infill, acoustic infill, seals and ironmongery are often split between trades. Write the split into the order.

Across the built-in furniture range, product listings state made-to-measure sizing with material and finish options and layouts tailored to the project. That flexibility is useful only if the dimensions and specifications are confirmed for each opening before production starts.

How a supplier works from your drawings and site data

When the drawing set and the site measurements agree, the route to a delivered panel system is short. The workflow described on the one-stop furniture and building materials page runs in five visible steps:

  1. Brief and drawing review. The panel schedule is read against the room layouts, wall builds and floor levels, and conflicts are flagged back to the design team rather than quietly worked around.
  2. Specification confirmation. Panel substrate, veneer or lacquer finish, hardware type, track fixing method and any acoustic or glass infill are fixed in writing per opening.
  3. Shop drawing sign-off. Shop drawings show panel sizes, joint positions, stack order and hardware. The design team or contractor returns them signed before cutting starts.
  4. Production and inspection. Panels are manufactured to the signed dimensions and checked against the schedule before packing.
  5. Delivery and installation support. Freight is arranged door to door, and installation guidance follows the same drawings that governed production. Installation and after-sales support covers on-site fitting, inspection of snags, spare parts and maintenance.

Where a project needs a non-standard panel build-up, a specific veneer or hardware that is not in the catalogue, custom and OEM service covers bespoke finishes, prototyping and manufacturing to the client's detail. The same applies when panels must match existing joinery on a renovation: send the sample or the drawing, and the finish is matched to that reference.

A coordination checklist before production release

  • Every opening has a unique mark that appears on both the drawing and the panel schedule.
  • Finished floor and wall levels are shown, and re-measured on site after wet trades finish.
  • Track type and fixing structure are agreed with the builder, with blocking installed before walls close.
  • Panel stack direction is checked against furniture layouts, so panels do not hit beds, vanities or wardrobes when open.
  • Finish samples are approved in the project's light conditions, and grain direction is drawn.
  • Glass, acoustic infill, seals and ironmongery are assigned to a named supplier for each opening.
  • Shop drawings are signed by the party that controls the design intent, not just received.
  • Delivery route, dock or lift capacity and storage area on site are confirmed before panels ship.

Panel dimensions, hardware selections and performance requirements are confirmed per project. Published product pages for these systems list made-to-measure sizing and finish options rather than fixed sizes, load ratings or acoustic figures, because the correct values depend on the opening, the structure behind it and the configuration selected.

Frequently asked questions

When should sliding panels be introduced into a project?

At design development, before the wall builds and floor levels are fixed. Introducing them at the end of construction usually means compensating for openings that were never dimensioned for a track.

Can panels match existing joinery on a renovation?

Yes, where a sample or an existing panel can be referenced. Veneer species, cut, grain direction and lacquer sheen are matched to that reference under the custom and OEM route.

Does the price cover panels only, or panels with tracks and hardware?

A system is normally quoted as panels plus track, hardware and fixings, with the split of responsibility written into the order. If a local specialist supplies the hardware, its load and travel requirements are confirmed before the panels are sized.

How are measurements taken for a made-to-measure order?

From the finished surfaces, after all wet and floor finishes are complete, with three readings per opening. Production works from those figures against signed shop drawings rather than from nominal drawing dimensions.

Send the panel schedule and room layouts

Share the drawings, finished levels and finish references for a villa, hotel or office project, and a specification comes back with shop drawings for sign-off. Contact SANTERSON through the contact page, or review completed work in the project cases.