A pergola submittal is the document set a consultant or main contractor reviews before they approve a product for purchase. For a motorized louvered aluminum pergola with LED strip and zip screens, the submittal has to do more than show a picture of an attractive structure. It has to prove that the rotating roof, the lighting circuit and the side screens can be built, wired, delivered and maintained exactly as drawn. Below is the package we prepare for each project, section by section, so procurement teams know what to ask for and specifiers know what to expect back.

A useful test before you request a submittal: could a site supervisor install this pergola and an electrical contractor terminate its wiring using only the documents supplied? If any answer requires a phone call, the package is incomplete.

1. Project data sheet and scope statement

The first page states what is being approved and where. It names the project and location, the building area or terrace the pergola sits in, the supplier of record, the drawing revision number and the date, and the person responsible for coordination on site. It also lists which items are inside the supply scope and, just as importantly, which are not.

For pergolas we normally describe the scope as frame, louvers, motorised drive, integrated LED lighting, zip screens where specified, fixings and installation documentation. Anything beyond that — a concrete slab or footing, an electrical spur to the pergola, a balustrade at the terrace edge, or a waterproofing membrane below the structure — is stated separately so the responsibility boundary is visible rather than assumed.

2. Dimensional drawings and bay layout

Dimensioned plans, elevations and sections follow. A pergola is almost never a single standard unit; it is assembled from bays to fit the terrace, so the drawings show bay count, bay width, overall length and depth, post spacing, clear height under the beam, and post centres relative to the finished floor levels on site.

The detail drawings carry the information reviewers actually mark up: post profile and wall thickness, beam and gutter profile, louver blade profile and overlap, the rotation axis of each blade, and how adjacent bays join. We prepare these against the design intent for each project, because custom furniture design and prototyping is part of how we work — bay dimensions, frame colour and screen transparency are set to match the drawing rather than chosen from a fixed catalogue.

Anchor details belong in this section too: base plate geometry, bolt type and diameter, edge distances, and the fixing method for the substrate actually present on site. If the terrace is a suspended slab with waterproofing, the detail shows how the post base is set out so the membrane is not penetrated where it should not be.

3. Louver and drive system specification

The louvers are the part that wears out or works well, so their specification is reviewed line by line:

  • Blade material and finish — aluminium blades with the specified powder-coat colour, including the underside colour where a dual-colour frame is required.
  • Blade size, wall thickness and the maximum unsupported blade span for the bay width being quoted.
  • Rotation range, from fully closed to fully open, and the direction of travel when power is removed.
  • Drive arrangement — motor make and model, gearhead, torque rating, how the motors link blades across a bay, and whether bays are driven individually or ganged.
  • Control method — wall switch, remote, or building management integration, plus what interface is provided and what interface the electrician must supply.
  • Rain or wind sensing where requested, with the trigger device identified rather than described generically.

We state the closed-roof behaviour in plain words — louvers close to form a watertight roof against light rain — and note that drainage runs through the integrated gutter rather than through the blade joints. If a project needs a different performance level, that is discussed at quotation stage, not discovered during review.

4. LED lighting package

Integrated strips remove the need for separate light fittings and keep the lines clean, which is why they are specified so often on rooftop bars and spa terraces. The submittal treats them as an electrical installation, not a decorative extra:

  • Strip type, colour temperature and whether a tunable or single fixed temperature has been chosen.
  • Mounting position — inside the blade channel, along the beam face, or in the gutter line — with a section showing how the strip is concealed and how it is serviced.
  • Driver location, driver accessibility for maintenance, and the length of each run so voltage drop can be checked.
  • Ingress protection rating of strips and drivers for an exposed outdoor position, and the connection method between runs.
  • Switching and dimming arrangement, including which circuit is on which control.

A simple one-line wiring schedule at the end of this section prevents most site confusion: every circuit, its driver, its switch and its power source.

5. Zip screens: fabric, hardware and exposure

Zip screens are fitted to whichever sides the design calls for, to cut low sun and breeze and improve privacy without fully enclosing the space. The submittal records the panel width and drop for each side, the housing and guide-channel profile, the operating method, and how the fabric is tensioned.

Fabric data matters more than fabric names. We give the composition, weight, openness factor, colour against a physical sample reference, and how transparency was selected for the orientation of that terrace. Where a project requires specific fire or weather performance for the fabric, we confirm the applicable requirement with the specifier and provide documentation for it rather than quoting a generic claim.

Wind exposure is the question reviewers ask most often about screens. The submittal states which sides are sheltered and which are exposed, the operating limits recommended for the screens, and the fixing detail for the guide channels into the structure and into the ground or slab.

6. Materials, finishes and corrosion protection

This section lists frame alloy and temper for posts and beams, blade material, fixings grade, and the finish system with its layers — pre-treatment, primer and top coat — plus the colour reference used for approval. Hardware in contact with aluminium is called out separately to avoid dissimilar-metal corrosion.

Because pergolas are supplied into coastal and high-humidity sites as well as inland ones, we ask which environment the structure will sit in before selecting the finish and hardware grade, and we record that decision in the submittal so the same basis applies at production.

7. Structural design basis and interface requirements

We state the loading assumptions used for the frame — dead load, snow where relevant, wind on louvers in both open and closed positions, and any maintenance access load — together with the standard the design follows and the designer of record. The reviewer can then confirm those assumptions against the site's own structural criteria instead of taking them on trust.

Interface requirements sit beside them: minimum slab thickness and edge distance for anchors, whether the post bases bear on a finished surface or a screed, tolerance for level adjustment, and clearances needed for the screens to travel. Any item that must be verified by the project's own engineer is flagged as such.

Where a local authority, certifier or client engineer requires stamped calculations for the frame or its fixings, we arrange them for that specific project during the design stage. We do not present another project's certification as covering this one.

8. Samples and mock-up

A submittal is easier to approve when the reviewer can hold part of it. We supply a louver blade sample showing the finish on both faces, a powder-coat panel in the approved colour, a fabric swatch for each screen side, and a short section of LED strip with its diffuser so the light line can be judged at close range.

For hospitality projects we also offer a small mock-up bay or a partial assembly before full production, so rotation, lighting appearance and screen operation are signed off in person. It is an option rather than a requirement, and it removes most change requests later.

9. Packaging, delivery sequence and site access

The logistics section shows the packing list by crate or bundle with weights and dimensions, the crate marking system that ties each package to a drawing reference, and the delivery sequence if bays are installed in a set order. It also notes the lifting or handling method at the point of unloading and any access limits we need from the contractor — crane availability, lift capacity, or a rooftop route.

Our logistics and door-to-door delivery service covers freight forwarding by sea, air and rail with the associated paperwork and container loading plans. Incoterms, port of entry, duties and the delivery address are confirmed per project and recorded in this section so nobody assumes a different term at despatch.

10. Installation method statement and maintenance plan

The installation document gives the assembly sequence, setting-out procedure, torque values for bolted connections, anchoring procedure, electrical termination steps, commissioning checks — rotation through the full range on every bay, lighting circuits tested, screens run through their travel — and the tolerance limits to be recorded at handover. It names what must be inspected before the structure is loaded or enclosed.

The maintenance plan tells the owner's facilities team what to do after handover: cleaning intervals for blades and gutters, drainage checks before the wet season, lubrication points, recommended operating limits for the screens, and the spare parts that should be held on site — drive components, strip sections, drivers and screen fabric by metre. Our installation and after-sales support covers on-site installation guidance, inspection and snagging, warranty coverage and spare parts supply; the specific warranty term and response arrangement for your project are set out in writing with the quotation.

How to read the submittal: a reviewer's checklist

SectionWhat the reviewer confirmsCommon gap to look for
Project data sheetThe right product, revision and scope boundarySite works listed as included when they are not
Dimensional drawingsFits the terrace, posts clear doors and balustradesNo finished floor levels or no anchor detail
Louver and driveTorque, control method and fail-safe behaviourMotor described generically with no model data
LED lightingIP rating, driver access, circuit scheduleDriver sealed where it cannot be reached
Zip screensFabric openness, exposure, guide fixing detailNo operating limits for exposed sides
Structural basisLoading assumptions match site criteriaAssumptions not stated at all
Delivery and installationCrate sequence matches build sequenceNo lifting or access information

Ordering information you should fix before production

Three decisions change price and lead time, so we ask for them at approval stage rather than at despatch: the finished frame colour including any dual-colour requirement, the screen transparency and side arrangement, and the control method for both louvers and lighting. Confirming these against signed drawings avoids the one change that is expensive after cutting — a different bay width.

Minimum order quantities are flexible across our range and are confirmed per project along with the production schedule; the figure we quote in writing is the one that applies to your order.

Frequently asked questions

Can the pergola be supplied without zip screens and added later?

Yes, and we can detail the structure so screen housings and guide channels can be fitted at a later date. The submittal should then show the provision as part of the frame now, so the later addition does not require new fixings into a finished surface.

Does the closed roof hold water?

Closed louvers form a watertight roof against light rain, with water leaving through the integrated gutter. It is a shelter, not a sealed enclosure, and any requirement beyond that should be raised at specification stage.

Who provides the electrical connection?

We supply the drivers, wiring looms and control arrangement inside the structure and document where the supply terminates. The spur from the distribution board, protective devices and any building management interface are provided by others, and the submittal states that boundary explicitly.

Can this pergola be coordinated with other outdoor furniture on the same terrace?

Yes. Coordinating the shelter with outdoor furniture for villas and resorts — loungers, dining sets, daybeds and swing benches — is part of our one-stop supply model, which reduces the number of separate submittals a project has to review. See our one-stop furniture and building materials supplier service for how that scope is assembled.

If you are preparing a specification or reviewing a tender, send us the terrace drawing and the performance requirements you need met. We will return a submittal covering each section above, with the assumptions stated rather than implied, so approval can proceed on documents instead of correspondence.