Aluminium honeycomb panel is one of those materials that looks simple on a specification sheet and becomes complicated on site. Two thin aluminium skins bonded to an aluminium honeycomb core give a board that is stiff, flat and unusually light for its size, which is why it appears on exterior facade and interior wall cladding in hotels, offices and retail interiors. The difficulty is not the material concept; it is that a cladding package is only as good as the information supplied with it. Panel size, substrate condition, fixing method, finish and the interface details all have to be settled before production starts.

The list below is the set of inputs we ask for on commercial projects so that a honeycomb cladding proposal can be quoted, engineered and shipped without rework. It applies whether the panels are going onto an external facade, a lift lobby, a reception feature wall or a partition line in a shopping mall.

1. The measurements that actually drive the price and the build-up

Send drawings rather than a single square-metre figure. A take-off from marked-up elevations tells us far more than an area total, because two walls of identical area can need completely different panels.

  • Floor-to-floor heights and panel orientation. Vertical or horizontal laying changes joint counts, module widths and how the panels meet ceilings and skirtings.
  • Module width and maximum panel size. Honeycomb panels can be made in large formats while keeping flatness, but the practical limit is set by your substrate grid, transport constraints and who is fixing on site, not just by the press.
  • Total developed area plus a cut-off allowance. Give the net cladding area from drawings and state whether you want us to allow for wastage or whether your contractor will cut on site.
  • Substrate type and evenness. Concrete, masonry, steel frame or backing battens each take a different fixing detail. Where the existing wall is out of plane, tell us the deviation range so we can design the subframe rather than guess it.
  • Openings, reveals and corners. Window reveals, door heads, internal and external corners, returns and any curved sections need to be dimensioned individually. Curved cladding in particular changes the core specification, so flag it early.
  • Interface dimensions at ceiling, floor and adjacent materials. Shadow gaps, trims and cappings are decided here, and they are the most common cause of a second production run.

2. Interior or exterior: what changes in the build-up

The same basic sandwich is used inside and out, but the exposure decides the finish system and the fixing hardware. For external facades and curtain-wall applications, the surface coating and edge detailing are chosen for long-term weathering and corrosion resistance, and the panel is designed around an open or closed joint detail with a drainage path behind it. For interior wall decoration and partition panels in malls, offices and hotels, the focus moves to surface appearance, joint sharpness and how the panel behaves next to lighting, joinery and skirtings.

Honeycomb construction is also chosen where acoustic separation and fire performance matter in the build-up. Those are project-specific claims, and we treat them that way: the performance you need should come from your own project specification and local requirements, and we will confirm what our standard build-ups offer against it before production rather than after.

3. Finish inputs: surface, colour and texture

Finish is a separate decision from panel engineering, and it needs its own inputs.

InputWhat to provide
Surface typeSolid colour coating, metallic or textured coating, perforated face (and if perforated, the hole pattern, open area and whether the perforation is through the outer skin only).
Stone look or stone veneerNatural stone veneer faces behave differently from coated aluminium. Name the stone, slab thickness and whether you need a matched batch.
Colour referenceA brand and code is helpful, but a physical sample or a RAL/Pantone reference plus a gloss level is safer. Screen renderings on a screen are not a colour specification.
Sheen and textureMatte, satin or high gloss, and whether the surface will be seen in raking light or next to feature lighting, which exposes every roller mark and slight bow.
Siting of the sampleTell us where the panel will be used. A finish that reads well in a lobby often looks different on a sunlit facade.

4. Fixing and subframe inputs

Cladding fails at the fixing, not at the panel. Before we can produce shop drawings we need to know how the panels are intended to be held.

  • Who designs and supplies the subframe: us, your facade contractor, or your general contractor.
  • Fixing method: mechanical angle brackets, clip-and-rail systems, or adhesive where the substrate and panel size allow it.
  • Joint design: open joint with a visible shadow gap, closed butt joint, or a trim-capped joint. Give the intended gap width.
  • Access requirements: panels that must be demountable for plant access need a different fixing from fixed panels, and this has to be resolved before cutting.
  • Site conditions: working height, whether scaffolding or a boom lift will be used, and the sequence of trades around the cladding package.

5. Project inputs beyond dimensions

A few non-dimensional items determine lead time and packaging more than anything on the drawing.

  • Quantity and phasing. One lift lobby now and a full floor later is a different production plan from one complete run.
  • Destination and delivery terms. Port or site address, container limits at the delivery point, and whether the panels must arrive in crate order matched to room numbers or elevation marks.
  • Marking and bundling. Panel-by-panel marking against your elevations saves days on site; tell us your numbering convention or let us propose one.
  • Approval route. Name the party who signs off the sample panel and shop drawings, and how long that normally takes. Sample approval is the step most often left too late.

A practical sequence for specifying the package

For most projects the workable order is: send marked-up elevations and the substrate description; agree panel modules, joint design and finish from a physical sample; issue shop drawings for sign-off; then release production. That sequence follows the same route our custom and OEM service uses for made-to-order products, with detail confirmation before manufacture.

Because cladding is usually bought alongside other finishes, we normally handle it in the same package as the surrounding scope. The honeycomb panels sit in our range of wall panels and wall cladding, next to decorative panels, timber veneer panelling and flexible stone veneers, and alongside ceiling panels where the same aluminium systems continue overhead. Coordinating those items with one supplier keeps finishes, joint details and delivery dates consistent across the facade and interior lines, which is the point of our one-stop furniture and building materials supply for villa, hospitality and office projects.

Before you send an enquiry. Have the elevations, the substrate description, the finish reference (physical sample or code plus gloss level) and your panel numbering convention ready. With those four items, a honeycomb cladding enquiry can move straight to shop drawings instead of another round of questions.

Send us your elevations

SANTERSON is a China-based manufacturer and one-stop supplier of furniture and building materials, producing aluminium honeycomb panels to project-specific sizes, finishes and fixing details. Email the drawings and finish reference to santerson@qq.com, or contact PHILLIP on WhatsApp +86-13928214007 for a quotation and shop drawings.