A glass partition looks simple on a drawing. Clear panel, slim frame, clean line. That simplicity is exactly why finish decisions get left until late, and why a colour that reads well on a specification sheet can look wrong once it is installed against a bathroom wall. Reviewing physical finish samples before production starts is the step that removes most of that risk. It is also inexpensive compared with re-manufacturing panels that have already been cut to size.

Our Glass Partitions are made to measure for each project, with the finish, layout and dimensions specified by the buyer rather than fixed by a standard catalogue size. That freedom is useful, but it means the sample review is where the specification becomes real. Here is how we suggest you run it.

1. Request samples in the actual finish, not a printed card

Ask for the sample to be produced by the same process that will be used on your panels. A printed colour card can approximate a powder coat or a metallic frame tone, but it cannot show how the surface behaves under light. For frame finishes, request a coated section of profile rather than a flat swatch, so you can see the edges, the corner joints and any build-up at the corners.

  • Glass tint: clear, bronze, smoked, grey or ribbed. Tint depth changes noticeably with panel thickness and with the light behind the panel.
  • Frame finish: aluminium frame tones in matt, gloss or textured, checked at both the face and the edge.
  • Surface texture: where a textured or ribbed glass is specified, confirm the direction and depth of the pattern.

2. Judge the sample on site, in the real lighting

A sample viewed in a showroom or an office will not match what you see in the completed bathroom. Tape the sample to the actual wall or tile it will sit against, and look at it at three times of day. Then check it under the artificial lighting that will be used at night, which is where most partition frames are actually seen.

Two checks matter more than the rest. First, hold the frame sample against the tile, stone or wall panel finish that surrounds it; a frame tone that looked neutral can pull warm or cool once it sits next to a large surface. Second, sight the glass sample from the viewing distance you will normally use, with something solid placed behind it. Glass tint is judged against what is on the other side of the panel, not against the table it was lying on.

3. Put every approved finish in writing before cutting starts

Once a sample is accepted, record it. Verbal approvals are where disputes begin. Keep the physical sample itself, signed and dated, and match your written specification to it rather than to a colour code alone.

Item to confirmWhat to record
Glass type and tintTint name, thickness as confirmed for the opening, and which side the finish is applied to where relevant
Frame colour and sheenFinish name, gloss or matt level, and the retained physical sample reference
HardwareHandles, hinges, tracks and any closing hardware, in the same finish family as the frame
DimensionsOpening sizes as measured on site at the time of order, including floor and ceiling conditions
LayoutPanel positions, fixed versus opening panels, and door swing or sliding direction
Edge and joint detailHow edges are finished and how the frame meets wall and floor finishes

Where the partition is part of a wider set of built-in work, review its samples alongside the matching items at the same time. Frames, wood panel partitions and panelling specified for the same bathroom should be approved as one group, so that tones which are meant to read together actually do.

4. Confirm the dimensions at the same review, not later

Finish approval and dimensional sign-off should happen in one pass. Made-to-measure partitions cannot absorb site variation once the panels are cut, so the openings should be measured after wall finishes, floor levels and ceiling heights are settled. If tiling or flooring is still open, say so at the review meeting and record which party confirms the final sizes and when.

For sliding configurations, tracks and hardware need the same treatment as the visible finish: confirm the track type, the running gear and the clear opening width before production. These items are usually decided from a specification line rather than a visual sample, which is why they are easily missed.

5. Use one approval document for the whole partition package

Send a single sign-off sheet listing each approved finish, its retained sample reference, and the confirmed dimensions, then have it returned signed. If you are coordinating partitions alongside other fit-out items from the same supplier, that document also becomes the reference point for delivery sequencing and installation, since partition frames typically need to arrive after wet trades and floor finishes are complete.

Before you approve: check that every finish on your drawing has a corresponding approved sample. Panels ordered from a specification that was never sampled physically are the most common source of a finished bathroom that does not match the design intent.

Getting samples for your project

SANTERSON has supplied furniture and building materials to projects since 2008, working as a one-stop furniture and building materials supplier across villas, hospitality and office developments. For partition work we handle specification, sampling, production, packing and delivery as one package, so the finish you approve on a sample is the finish that reaches site.

Send us your drawings, the surrounding wall and floor finishes, and the openings you need glazed, and we will return samples of the proposed glass tint, frame finish and hardware for review before any panel is cut.

Talk to us about partition sampling for your project.

Contact: PHILLIP  |  Phone / WhatsApp: +86-13928214007  |  Email: santerson@qq.com

SANTERSON — Glass Partitions, Custom Partitions & Paneling collection, made to measure for each project.