A quotation for a washdown one piece toilet is easy to compare on price and hard to compare on fitness. Two offers can carry the same model number, similar unit rates and the same lead time, yet one of them will not fit the drainage that your site already has. Before you sign a purchase order for the Modern Ceramic 1003A Toilet, work through the checks below in the order a project actually fails: drainage first, then specification completeness, then documentation, then packaging and spares.

Start With Drainage, Not With the Bowl

The 1003A is offered with two installation types: a P-trap wall drain at 180mm rough-in and an S-trap floor drain at 250mm rough-in. That single line in the specification decides whether the unit can be installed at all, so treat it as the first number to verify rather than a footnote.

Before requesting quotations, have the site team record, for each bathroom type:

  • Whether the waste outlet leaves through the wall or through the floor.
  • The measured rough-in distance from the finished wall face to the centre of the outlet, and whether that measurement was taken off the finished surface or the structural one.
  • Whether the finished wall build-up (tile, adhesive, backer board, framing) has already been accounted for in that dimension.

Then send those figures to the manufacturer with your enquiry and require the reply to state which trap option is being quoted. A proposal that simply repeats the catalogue sentence "P-trap and S-trap available" has not answered your question. One that states, per item code, which rough-in will be shipped has.

If a project mixes both conditions, ask whether the trap variant is a separate order line with its own quantity, or one mixed line. Mixed lines are where short shipments show up later: the floor-drain rooms get their units and the wall-drain rooms do not.

Read What the Specification Covers, and What It Leaves Out

The published description for this model gives you vitreous ceramic with a glossy glaze, a one-piece seamless body, washdown flushing, the two trap options above, and CE certification. That is enough to shortlist the product. It is not enough to order from. Compare each proposal against a fixed list of items and mark what is stated, what is implied and what is missing.

ItemWhat a usable proposal states
Trap type and rough-inThe option being supplied per order line, matched to your site measurement
Overall dimensionsWidth, depth and height with the tolerance or measuring method noted
Flush mechanismFlush volume or range, actuator side, seat fixings and replacement part reference
SeatIncluded or excluded, material, soft-close or standard, colour
Fixing setWhether floor or wall fixings, anchors and seals are packed with the unit or ordered separately
Certification referenceThe certificate itself and the model name on it, not just a claim in text
PackagingPer-unit protection, carton marking, pallet pattern for mixed trap variants
Defective-unit handlingEvidence required, who bears freight, replacement lead time

Where a line is missing, ask for it in writing before award. A supplier who answers these questions cleanly at quotation stage will answer them cleanly during production; one who waves them away usually will not.

Match the Product to the Room Type

A one-piece washdown WC in a guest bathroom of a villa and the same unit in a high-turnover commercial restroom are not doing the same job. In residential and villa bathrooms, the seamless body matters most for housekeeping: with no crevice between pan and cistern there is nowhere for grime to collect, and the glazed surface resists yellowing under routine cleaning. In hotel and commercial washrooms, the practical questions shift to maintenance access, replacement-part availability and how the unit behaves when cleaned daily by staff rather than weekly by an owner.

Where a proposal is intended for a hospitality or commercial scheme, ask the manufacturer to say plainly whether this model is being offered for that duty level, and which of their other WCs they would put forward if it is not. Their answer tells you how well they understand their own range.

It is also worth checking the alternatives in the same family before you commit. The catalogue lists a wall-hung WC with 180mm P-trap rough-in for bathrooms where an empty floor line and a compact footprint matter, and a two-piece washdown WC with dual S-trap and P-trap options for schemes where a separate cistern arrangement is preferred. If your draughtsman never saw those options presented, the proposal was written from a catalogue page rather than from your drawings.

Check the Paperwork Before the Price

Certification claims need documents behind them. The 1003A listing carries CE certification; ask for the certificate and read the model designation printed on it. Where a range uses close variants, the name on the certificate and the name in the quotation can differ slightly, and customs officers compare the paperwork rather than the marketing page. Confirm that the model name you are ordering, the name on the certificate and the name on the packing list and commercial invoice are the same string of characters.

The same discipline applies to technical drawings. Request a dimensioned drawing for the exact variant being quoted, and pass it to your plumbing consultant to check against the waste set-out on issue-for-construction drawings. This is a small cost in time and the usual point at which a rough-in mismatch gets caught.

Ask too what happens when a unit arrives cracked. Ceramic travels well when it is packed properly and badly when it is not, so the practical test of a supplier is not whether damage never occurs but how quickly they replace it: photographic evidence required, who pays the freight on the replacement, and whether a spare allocation can be held for the project.

Order Quantities and Spares Like a Project, Not a Shop

  • Round up on bathroom types that repeat many times, and keep trap variants as separate lines so counts can be reconciled room by room.
  • Hold one or two spare units per repeating type for post-handover replacement; matching a discontinued variant years later is far harder than storing a couple of cartons on site.
  • Ask for carton marking by trap type and room type where the scheme allows, so installers are not opening boxes to find out which unit they have.
  • Agree inspection at delivery, with a defined window for reporting concealed damage.

A Pre-Award Checklist

  • Trap type and rough-in confirmed against a finished-surface measurement for every bathroom type.
  • Dimensions, flush mechanism, seat inclusion and fixing set stated per order line.
  • Certificate supplied, with the model name matching the quotation, packing list and invoice.
  • Dimensioned drawing reviewed by the plumbing consultant against site set-out.
  • Duty level confirmed for residential or commercial use; alternatives proposed where it does not fit.
  • Packaging, carton marking, damage procedure and spare-unit supply agreed in writing.

Figures such as rough-in distances follow the published product listing and should be re-verified against the current technical sheet for the batch being ordered before any purchase order is issued.

Buying Sanitaryware as Part of a Larger Package

If the WC is one line in a wider fit-out, evaluate the proposal as part of that package rather than as an isolated item. Coordinating ceramics with vanities, basins, shower sets, lighting and joinery from a single interior fixtures programme reduces the number of separate deliveries to track and keeps finishes consistent across rooms. Where that route is used, still apply the drainage and documentation checks item by item; a bundled quotation should not mean a bundled specification.

SANTERSON has been manufacturing furniture and building materials since 2008 and supports projects from design and production through to door-to-door delivery and installation support. Send your room set-out drawings with the enquiry rather than a model list, and judge the reply on how many of the checks above it answers without being asked.

Send your bathroom set-out drawings and required quantities for a specified proposal.

Contact: PHILLIP  |  Phone / WhatsApp: +86-13928214007  |  Email: santerson@qq.com

Enquire about sanitary ware for your project